Buspro is a protocol based on RS485 connection topology for intelligent buildings. Buspro was developed using 64 bits as a long code, 32 bits as short code, targeting to become the Asian and African standard protocol as administered by HDL automation. In the past "Buspro" was known as S-BUS and sbuspro. Wire transmission Twisted pair of data using signaling speed of 9600 bit/s. flexible power with 8-32 V DC, and 25 mA, polarization critical. Can be installed with up to 250 Devices in each bus group with 254 subnets, linking with network bridges, up to 65280 device per network, Maximum bus length is 1600 m. Technology Buspro is a patented protocol (Patent No: 201110123081.0) based on "Advanced RS485" 64-bit communication. This two-way communication protocol was designed mainly for home automation industry and thus many call it today "Buspro". The Buspro system can drive Many Hardware devices, Command, Monitor and Control them simultaneously in smooth and confirmed 2-Way Communication ability using Simple 4-core twist Pair Data Cable that is widely available in the market. Buspro has Multi Edge technology to Easily communicate with multi nodes; Wirelessly via the "Buspro wireless" in what is called the "Mesh". Topology Using Buspro Technology, installers can connect up to 250 Devices on One Cable that can reach in length up to *(1600 meters). and up to 64000 devices on a single RSIP Network Bridge. where over 16,000,000 can be monitored and controlled in one network of 250 bridges, meaning that, if installer link Several Buspro Loops together using network bridges, then up to 65280 devices per network Bridge can be smoothly linked and up to 254 loops likewise can be networked together as one Body. Buspro has very flexible connectivity: It uses Mainly Daisy Chain, it can be either an Open or closed Loop/Ring, Can Work in star Topology wiring, or Even Grid or Mesh. Protocol format: (ASCII): bits protocol according to the code tables Function - Control order operation * Answer order operation Parameter 1 Parameter 2 Parameter ? Scene 0x0002 0x0003 Area Scene No Sequence 0x001A 0x001B Area Series No Universal switch 0xE01C 0xE01D Universal switch No Switch status Single channel adjustment 0x0031 0x0032 Channel No Brightness value Running time is composed by?Byte MAX:????S, default : ?S Curtain switch 0xE3E0 0xE3E1 Curtain No Curtain status Infrared switch 0xE3D0 0xE3D1 Group No Group value Resend times and on/off SMS control 0xE3D4 0xE3D5 1?message 2?remote Series No Panel control 0xE3D8 0xE3D9 1?infrared enable 0?off?1?on 2?panel lock key 0?off?1?on 3?AC Power 0?off?1?on 4?AC cooling temp C?18-30?F?64-86 5?AC wind speed 0?auto?1?high?2?mid?3: low 6?AC mode 0?cool?1?heat?2?vent?3?auto 7?AC heating temp C?4-26?F?39-79 Infrared long code switch 0xE3DC 0xE3DD Group No Group value Group location?1byte Design and idea Buspro was created as vision with clear targets to become the world’s new standard of automation Industry: # To have Open Protocol System # To Have a System that can Communicate with Thousands of Nodes # To Have a system that communicates easily over long Distances # To have a system that is Green and do not consume lots of energy # To have Smart system with 2-way communication, Monitoring and control. # To create a consortium of many manufacturers that can create solutions as PnP When designing the system, it was also mandatory to understand Installation complexity and protection and well as Tolerance needs: # Current Fluctuations in different Countries and Dirty Electricity # Variable Voltage and Frequency # Cable quality and Disturbances that require Big Operational Voltage Range # Overload Protection # Over Heat Protection # Reverse Polarity Protection # LV Port Protection # Short Circuit Protection # Mixed Wiring Topologies # Bothe New and Retrofit Installations # Easy Expandability # Simple Configuration and Upgrade # Modular compact size System # Multifunctional Devices for Flexible Stock Usage Learning from The Best: When Creating Buspro, Many Other Manufacturers and Giant Technologies where the source of inspiration, and the trigger of such system that is Almost bullet proof. As well known to many: * Internet is the Best in Bandwidth and Number of Nodes xxx.xxx.xxx.xxx (But internet Need Network Devices every 150 Meters in Average) * KNX is the Best in Open Protocol Concept and consortium Concept (But it is not Fully open) * RS-485 is best in Distances (BUT require special Topology) Buspro is the mix of best features from all: Buspro: as an Advanced RS-485 with flexible Topology and Super Long Distances that Embraces Internet Subnets Ability to connect More than 64000 Devices in one single Net, yet it is based on KNX Open concept. Industry Giants that we learned from, took their Best and Avoided their Mistakes became accordingly added value Contributors to our Design: * Delta Controls, (Modularity flexibility) * Clipsal C-BUS (Simplicity in Programing and Hand Pairing) * Dynalite (Scripting Multi functionality actions) * Bosch (Voltage Tolerance) * HAI (Security and Logic) * Crestron (IR and Integration) * Nuvo (Simplicity in Audio Distribution) * ELAN (Media and Special Sensors) * Control4 (Retro fit Solutions and Mesh Network) Issues avoided During Buspro Design: * End of Loop Terminators (Echo, and daisy chain) * Voltage Drop or Over Power Issues (Loss of communication, or burning of com Boards) * Central Wiring (Start Topology Issues) * Load Limitation Issues (Low Load handling ability of Retro) * Wifi and LAN Network Issues (Freezes, Security, Pro installers) * Short circuit Issues (Losses) * Stocking of Multiple Devices for Multiple Function (Different Device for Different Volt and Function) * Non Uniform Shapes of Fixtures (Wall Agony) * Professional Programmers and Scripters issues (Limitations and Costs) * Special cables (Cost and Availability) Other Issues that are also considered while designing the system: # Working in Dark Locations (No Power yet) # Working in Harsh Temperatures (Hot/Cold) # Some Installers are Color Blind # Sometimes cables are mixed with CCS, CCA or Other # Sometimes communication and control cables must pass with Electrical Runs. # Sometimes Installers connect loads then measure after its late # Many installers go Cheap or easy and do not install protection fuses and breakers Buspro when designed, it had all the above accounted for as the base and the standard for its topology, field devices, configuration and protocols. Buspro Operating Voltage: Buspro can work at wide Voltage DC Range between 8-32Volts. And is considered Green as it consumes between 20-32mA per device during operation. Buspro uses 4 Wires (2-Pairs): one Pair for Data Communication and the other for Power. The Smart-BUS has Also Several Lines of protection like: Reverse Polarity Protection, Short Circuit protection, Overload Protection, Overheat protection, and other.. Open Protocol: Buspro Patented Protocol is also an Open Protocol provided to Professional Developers and Integrators Free of Charge. (Any Registered Organization / Developer Can Easily and directly get the complete Protocol documents that they need after filling and Signing the proper Quality Network Paperwork). Buspro Enabled Devices and solutions: Several Home Automation and Building Control Devices are widely available worldwide today, and provided through several Developers and Manufacturers. Products One of the strengths of the Buspro protocol that Buspro have full and complete range of products with minimum wiring and devices. • Buspro Enabled Dimmers • Buspro Enabled Relays • Buspro Enabled Ballast Controllers • Buspro Enabled DMX-48, DMX-512 controllers • Buspro Enabled LED RGBW Drivers and Boosters • Buspro Enabled DALI Bridges • Buspro Enabled SMS Communication Modules • Buspro Enabled HVAC (Heating Ventilation and Air-Conditioning Control) • Buspro Enabled Ceiling Fan Speed Controllers • Buspro Enabled Temperature Sensors • Buspro Enabled Mini Weather Station • Buspro Enabled Pump Monitoring and Control • Buspro Enabled Multifunctional Sensors (Patented Technology) • Buspro Enabled Dry Input Devices • Buspro Enabled I/O Modules • Buspro Enabled Motor and Shades Control • Buspro Enabled Web Host with Chat Client • Buspro Enabled Multi-Room Distributed Digital Zone-Audio Network • Buspro Enabled Integration Bridges like RS-232/485 and TCP/IP, UDP • Buspro Enabled C-Touch Bridges for IP Video Intercoms • Buspro Enabled Doppler, Ultrasonic, HBS,Sensors • Buspro Enabled Android, i.phone, and i.pad Interfaces • Buspro Enabled WinXp,7,CE applications • Buspro Enabled Security and Safety monitoring Modules • Buspro Enabled Power Metering and Management Modules • Buspro Enabled Infra Red Multimedia Controls • Buspro Enabled Hotel Guest Room Management system. (GRMS) • Buspro Enabled Air Quality and Health Monitoring Devices • Buspro Enabled Irrigation and Water Leak or Water Management & Control • Buspro Enabled Advanced Systems Bridges like KNX/EIB, Nuvo, Honeywell, Crestron, Control4, ELAN,..etc. • Buspro Enabled Mixed usage Controllers, Zone Controllers • Buspro Enabled DIY Zone Control Devices • Buspro Enabled Automation Logic and central Clock System • Buspro Enabled Dynamic Display Panels
|
|
|